Performance Dynamometer

Rotor Glow

Control system

  • Inertia setting 0 - 128±2 kgm2
  • Simulated vehicle speeds up to 200kph
  • Pressure control 0 - 17MPa ± 0.05MPa
  • Torque control 0-3000Nm ± 20Nm
  • Cooling wind speed 10 - 120k± 3kph

Measurement system

  • Pressure 0 - 17MPa ± 0.04MPa
  • Torque 0 - 3000Nm ± 0.5% of reading
  • Fluid Displacement ±0.02cc
  • Rotor thickness variation (RTV) 0-0.5mm ± 0.001mm
  • Temperature 0-700 ± 2 degrees celcius

DTV Dynamometer - 10 Station

This machine will simultaneously test Qty 10 brakes-off DTV samples.

Full time operation of this dynamometer will facilitate 500 DTV test per annum.
It can also be adapted for drag, fluid displacement, pressure pulse testing and housing deflection measurement.

Control system

  • Cotinuous drive-line torque 140Nm
  • Angular velocity 0 - 1000 RPM ± 2RPM
  • Pressure control 0 - 17MPa ± 0.05MPa

Measurement system

  • Angular velocity 0 - 950 RPM ± 2RPM
  • Pressure 0 - 17MPa ± 0.04MPa
  • Rotor thickness variation (RTV) 0-0.5mm ± 0.001mm

Drag Dynamometer

Drag  

This machine will simultaneously perform Qty 2 Drag tests.

It can also be adapted for pressure pulse testing and housing deflection measurement.

Control system

  • Continuous drive-line torque 140Nm
  • Angular velocity 0 - 1000 RPM ± 2RPM
  • Pressure control 0 - 17MPa ± 0.05MPa

Measurement system

  • Angular velocity 0 - 950 RPM ± 2RPM
  • Pressure 0 - 17MPa ± 0.04MPa
  • Torque 0-20 ± 0.1Nm

Website by Black Box Solutions